GENERAL

  • HUD Code
  • 20 lb. Roof Load Std., 30 psf optional
  • Thermal Zone 1 Std., zones 2 and 3 optional
  • Wind Zone 1 Std., zones 2 and 3 optional

FRAME

  • I - Beam: 12” or 10” model specific
  • Outriggers: 96” spacing
  • Crossmembers: 96” spacing
  • Header: (Front/Rear) Flush, not recessed
  • Axles: Spread (no equalizers) overslung mounted
  • Brake Axles: One, except where more are mandatory by state DOT
  • Hitch Beam: 8” Detachable Hitch

FLOOR

  • Joists: 2x6 / 19.2” o.c.
  • Carpet: Factory Select
  • Carpet Bar: None
  • Pad: 3.5 lb. (minimum) Rebond Pad
  • Vinyl: Factory Select
  • Decking: 19/32” 4x8 OSB T&G

EXTERIOR (7'-0" SIDEWALLS, 7'-0" ENDWALLS)

  • Vinyl Siding: Standard
  • Sheathing: WZ 1 - Foam standard, plant specific brand. WZ 2 & 3
  • Includes OSB
  • House Wrap: Over OSB (where used)
  • Shutters: None

WINDOWS AND DOORS

  • Front door: Out swing 34” x 76” blank, no storm.
  • Rear door: Out swing 32” x 76” blank, no storm.
  • Interior doors: Factory Select
  • Windows: Metal single glaze, size per prints.
  • Metal storm windows for thermal zone 2 and 3 only.

ROOF / CEILING

  • Design Load: 20 psf Live load standard, 30 psf options where needed
  • Shingles: 20 year
  • Trusses: 24” o.c. spacing
  • Sheathing: 7/16” OSB
  • Insulation: Blown Fiberglass
  • Ceiling: Textured
  • Ceiling Slope: Vault/Flat Ceiling
  • Attic Ventilation: Pot vents (low), Ridge vent high

PLUMBING

  • Water Heater: 30 gallon electric
  • Kitchen Sink: Stainless Steel, dbl bowl
  • Lavatory Sinks: Plastic
  • Faucets: Plastic
  • Master Bath: 54 ABS Plastic Tub
  • Hall Bath: 54 ABS Plastic Tub

HVAC

  • Heat: Electric (gas optional).
  • Ductwork: Metal duct
  • Thermostat: 8 Wire

ELECTRICAL

  • Load Center: 200 amp
    (100 amp allowed when gas option ordered – gas range and gas furnace).
  • Exterior Receptacles and Switches: (1) GFI recept and cover.
  • Interior Receptacles and Switches: White, self contained
  • Phone Jack(s): None
  • AC: Conduit

WALLS

  • Exterior Wall Construction: 2x4, 16” O.C. spacing
  • Ext. Wall Height Sidewall = 7’-0”, Endwall = 7'-0"
    (combo vault/flat ceiling, per prints)
  • Interior Wall Construction: 2x3, 24” O.C. spacing
  • Wall Coverings: 5/16” minimum VOG or paper on gyp
  • Wall Coverage at Closets: 5/16” gyp, raw

INTERIOR FEATURES

  • Cabinets: MDF / 24” tall overheads.
  • Countertops (All): Formica
  • Backsplash: None
  • Closet Shelving: Closet Maid – vinyl wrapped metal.
  • Utility Shelving: None
  • Refrigerator: 18 CF
  • Range: Electric
  • Range Hood: 30”, 100 cfm min, vent through sidewall.
  • Valance on LR windows only. No mini blinds

Request More Info

- -